Invertek ODE-3-320153-1042
Optidrive E3 Vector or Volts / Hertz Control
5.0 HP, 220 Volts AC, 1 Phase In, 3 Phase Out, IP20 (Nema1)
Brake Transistor
Optidrive E3 Vector or Volts / Hertz Control
5.0 HP, 220 Volts AC, 1 Phase In, 3 Phase Out, IP20 (Nema1)
Brake Transistor
Optidrive E3
AC Volts / Hz Variable Frequency Drive
5.0 Horsepower
Input: 200-240 Volts Single Phase, 29.2 Amps Nominal
Output: 200-240 Volts Three Phase, 15.3 Amps Nominal
Recommended Fuse / MCB Size (B-curve): Non-UL - 40 Amps UL - 40 Amps
Brake Transistor Fitted, Recommended Brake Resistance: 25 Ohms
IP20 (Nema 1)
Frame Size 3 - 10.28 in x 5.16 in x 6.89 in ( L x W x D ), 7.1 Lbs
Compact, Reliable and Easy to Use
Simply power on and Optidrive E3 is up and running, providing precise motor control and energy savings using the factory settings.
Precise and reliable control for IE2, IE3 & IE4 motors.
14 parameter basic setup. Default settings suitable for most applications. Contactor style connection for simple wiring.
Precise digital control at the touch of a button.
Switch between Industrial, Pump & Fan modes to optimise Optidrive E3 for your application.
An internal filter in every Optidrive E3 saves cost and time for installation.
Cat C1 according to EN61800-3:2004
Optidrive E3 Features
Innovative technology, reliability, robustness and ease of use in a range of compact IP20 & IP66 enclosures.
Precise and reliable control for IE2, IE3 & IE4 motors.
An internal filter in every Optidrive E3 saves cost and time for installation.
Cat C1 according to EN61800-3:2004
Application Macros
Switch modes at the touch of a button to
optimise Optidrive E3 for your application
Industrial mode optimises Optidrive E3 for load characteristics of typical industrial applications.
Pump mode makes energy efficient pump control easier than ever.
Fan mode (inc. fire operation) makes air handling a breeze, ideal for simple HVAC systems.
Output ratings | Typical Efficiency | > 98% |
Overload Capacity | 150% for 60 secs 175% for 2 secs |
|
Frequency | 0…500Hz, 0.1Hz resolution | |
Input Ratings | Supply Frequency | 48 - 62Hz |
Displacement Power Factor | > 0.98 | |
Phase Imbalance | 3% Maximum allowed | |
Power Cycles | 120 per hour maximum, evenly spaced | |
Ambient Conditions |
Temperature | Storage: -40 to 60°C Operating: -10 to 50°C |
Altitude | Up to 1000m ASL without derating Up to 2000m maximum UL approved Up to 4000m maximum (non UL) |
|
Humidity | 95% Max, non condensing | |
Vibration | Conforms to EN61800-5-1 | |
Ingress Protection | IP20 (Nema 1) | |
Programming | Keypad | Built-in keypad as standard Optional remote mountable keypad |
PC | OptiTools Studio | |
Display | 7 Segment LED | |
Control Specification | Control Method | Sensorless Vector Speed Control PM Vector Control BLDC Control Synchronous Reluctance |
PWM Frequency | 4 – 32kHz Effective | |
Stopping Mode | Ramp to stop: User Adjustable 0.1 – 600 secs Coast to stop |
|
Braking | Motor Flux Braking Built-in braking transistor (not frame size 1) |
|
Skip Frequency | Single point, user adjustable | |
Frequency setpoint control | 0…10 VDC 0…20mA 4…20mA Motorised Potentiometer (Keypad) Modbus RTU CANopen |
|
I/O Specification | Power Supply | 24 Volt DC, 100mA, Short Circuit Protected 10 Volt DC, 5mA for Potentiometer |
4 Total 2 Digital 2 Analog / Digital Selectable |
4 Total 2 Digital 2 Analog / Digital Selectable |
|
Digital Inputs | 8 – 30 Volt DC, internal or external supply Response time < 4ms |
|
Analog Inputs | Resolution: 12 bits Response time: < 4ms Accuracy: ± 2% full scale Parameter adjustable scaling and offset |
|
Programmable Outputs | 2 Total 1 Analog / Digital 1 Relay |
|
Relay Outputs | Maximum Voltage: 250 VAC, 30 VDC Switching Current Capacity : 6A AC, 5A DC |
|
Analog Outputs | 0 to 10 Volt | |
Application Features | Fire Mode | Bidirectional Selectable Speed Setpoint (Fixed / PI / Analog / Fieldbus) |
PI Control | Internal PI Controller Standby / Sleep Function |
|
Maintenance & Diagnostics | Fault Memory | Last 4 Trips stored with time stamp |
Data Logging | Logging of data prior to trip for diagnostic purposes: Output Current Drive Temperature DC Bus Voltage |
|
Bus communication | Modbus RTU | 9.6–115.2 kbps selectable |
CANOpen | 125–1000 kbps | |
Compliance with Standards | Low Voltage Directive | Adjustable speed electrical power drive systems. EMC requirements |
EMC Directive | 2004/108/EC Cat C1 according to EN61800-3:2004 |
|
Machinery Directive | 2006/42/EC | |
Conformance | CE, UL, RCM |