Invertek ODP-2-22010-1HF42
Sensorless Vector Control IP20 (Nema1) 1.0 HP
220 Volt AC, 1 Phase In @ 10.5 Amps, 3 Phase Out @ 4.3 Amps
EMC Filter & Brake Transistor
Sensorless Vector Control IP20 (Nema1) 1.0 HP
220 Volt AC, 1 Phase In @ 10.5 Amps, 3 Phase Out @ 4.3 Amps
EMC Filter & Brake Transistor
Type | AC Vector Variable Frequency Drive | |
Rating | 1.0 Horsepower | |
Input Current | 200-240 Volt Single Phase 10.5 Amps Nominal |
|
Output Current | 200-240 Volt Three Phase 4.3 Amps Nominal |
|
Options | Internal EMC Filter Brake Transistor Fitted |
|
Ingress Protection | IP20 (Nema 1) | |
Physical Dimensions | Frame Size 2 8.7 in x 4.4 in x 7.3 in ( L x W x D ) 3.97 Lbs |
Terminal | Function | Default Setting |
---|---|---|
1 | 12 Volt DC Output, 100mA max / 24 Volt DC Input | |
2 | Digital Input 1 | Drive Enable |
3 | Digital Input 2 | Forward / Reverse Select |
4 | Digital Input 3 | Preset Speed 1 Select |
5 | +10 Volt Power Supply 5mA | |
6 | Analog Input 1 | Speed Reference 0–10 Volt |
7 | 0 Volt | |
8 | Analog Output 1 | Motor Speed |
9 | 0 Volt | |
10 | Analog Input 2 | |
11 | Analog Output 2 | Motor Current |
12 | Safe Torque Off Input | |
13 | Safe Torque Off Input | |
14 | Output Relay 1 | Drive Healthy / Fault |
15 | ||
16 | ||
17 | Output Relay 2 | Drive Running |
18 |
Supply Voltage | 200 – 240V ± 10% 380 – 480V ± 10% |
|
Supply Frequency | 48 – 62Hz | |
Displacement Power Factor | > 0.98 | |
Phase Imbalance | 3% Maximum allowed | |
Inrush Current | < rated current | |
Power Cycles | 120 per hour maximum, evenly spaced |
Output Power | 230V 1 Phase Input: 0.75–2.2kW (1–3HP) 230V 3 Phase Input: 0.75–75kW (1–100HP) 400V 3 Phase Input: 0.75–250kW 460V 3 Phase Input: 1–350HP |
|
Overload Capacity | 150% for 60 seconds | |
Output Frequency | 0 – 500Hz, 0.1Hz resolution | |
Typical Efficiency | 98% |
Temperature | Storage : −40 to 60°C Operating : −10 to 50°C |
|
Altitude | Up to 1000m ASL without derating Up to 2000m maximum UL Approved Up to 4000m maximum (non UL) Above 1000m : Derate by 1% per 100m |
|
Humidity | 95% Max, non-condensing |
Ingress Protection | IP20 (Size 2, 3) IP40 (Size 8) IP55 (Size 4, 5, 6, 7) IP66 (Size 2, 3) |
Keypad | Built-in keypad as standard Optional remote mountable keypad |
|
Display | Optional OLED or LED display (OLED Display Multi Language) | |
PC | OptiTools Studio |
Control Method | V/F Voltage Vector Energy Optimised V/F Sensorless Vector Speed Control Sensorless Vector Torque Control Closed Loop (Encoder) Speed Control Closed Loop (Encoder) Torque Control Open Loop PM Vector Control |
|
PWM Frequency | 4 – 32kHz Effective | |
Stopping Mode | Ramp to Stop : User Adjustable 0.1 – 600 seconds Coast to Stop |
|
Braking | Motor Flux Braking Built-in Braking Transistor (Optional for frame sizes 6 & 7) |
|
Skip Frequency | Single point, user adjustable | |
Setpoint Control | Analog Signal | 0 to 10 Volts 10 to 0 Volts −10 to 10 Volts 0 to 20mA 20 to 0mA 4 to 20mA 20 to 4 mA |
Digital | Motorised Potentiometer (Keypad) Modbus RTU CANopen |
|
Optional | PROFIBUS DP, DeviceNet, EtherNet/IP, EtherCat, PROFINET, Modbus TCP |
Power Supply | 24 Volt DC, 100mA, Short Circuit Protected 10 Volt DC, 5mA for Potentiometer |
|
Programmable Inputs | 5 Total as standard (Optional additional 3) 3 Digital (Optional additional 3) 2 Analog / Digital Selectable |
|
Digital Inputs | 10 – 30 Volt DC, internal or external supply, PNP Response time : < 4ms |
|
Analog Inputs | Resolution : 12 bits Response time : < 4ms Accuracy : < ± 2% of full scale Parameter adjustable scaling and offset |
|
Programmable Outputs | 4 Total (Optional additional 3) 2 Analog / Digital 2 Relays (Optional additional 3) |
|
Relay Outputs | Maximum Voltage : 250 VAC, 30 VDC Switching Current Capacity : 6A AC |
|
Analog Outputs | 0 to 10 Volt 0 to 20mA 4 to 20mA |
Hoist Operation | Dedicated Hoist Operation Mode | |
PID Control | Internal PID control with feedback display |
Fault Memory | Last 4 Trips stored with time stamp | |
Data Logging | Logging of data prior to trip for diagnostic purposes : Output Current, Drive Temperature, DC Bus Voltage | |
Maintenance Indicator | Maintenance Indicator with user adjustable maintenance interval Onboard service life monitoring |
|
Monitoring | Hours Run Meter Resettable & Non Resettable kWh meters |
EN 61800-3:2004 | Adjustable speed electrical power drive systems. EMC requirements. | |
Low Voltage Directive | 2004/108/EC 230V 1 phase models category C1 according to EN61800-3:2004 400V 3 phase models category C2 according to EN61800-3:2004 |
|
Machinery Directive | 98/37/EC | |
Conformance | UL, cUL, C-Tick, ROHS, Gost |